Transducer Techniques donut load cell alternative.

Begin with the full THC model and bore suffix. Resolve the finished center bore, outside diameter, installed height and instrument before selecting a DLC-100 or custom configuration.

Review the original Transducer Techniques configuration ↗
DLC compression sensor interface concept for dimensional comparison
DLC concept illustration; not an original manufacturer product or approved replacement drawing.

Nominal shaft size is not the finished bore.

The original THC documentation distinguishes nominal labels from actual finished IDs. Record the suffix and toleranced drawing dimension; do not machine a replacement to the nominal fraction alone.

Confirm the original 2.00 inch outside-diameter installation and the full option code, then compare the remaining envelope and electrical requirements.

THC suffix reference: actual ID in inches and millimeters

Original manufacturer reference dimensions, not DLC stock sizes. Verify the drawing revision for the installed model.
Original suffixFinished ID (in)Finished ID (mm)
-P0.128 in3.251 mm
-Q0.193 in4.902 mm
-R0.266 in6.756 mm
-S0.391 in9.931 mm
-T0.532 in13.513 mm
-V0.656 in16.662 mm
Verify the current THC manufacturer reference ↗

Compare the electrical bridge before reusing the display.

List calibration excitation, sensitivity, zero balance, bridge resistance, wire / pin assignments and the receiving instrument. A matching raw mV/V label is only one item in the comparison.

Approved dimensional and electrical comparisons determine replacement suitability. Original brand names identify the installation under review; no affiliation or endorsement is implied.

Transducer Techniques fit and instrument questions

Why is the THC bore suffix needed for an alternative review?

The suffix identifies a finished clearance dimension. A nominal fastener size alone does not establish the actual bore, so provide the complete THC model and its current drawing.

Should I reuse the original THC instrument calibration?

Confirm input sensitivity, excitation, bridge resistance and wiring, then recalibrate the complete replacement chain. Stored or shunt calibration data must belong to the approved sensor configuration.

Send the full Transducer Techniques model, dimensions and output.

Configure the sensor, mounting and signal
Add the installation & measurement package

USD add-on reference prices supplied for quotation planning. Compatibility, selected configuration, freight and final commercial terms are confirmed in the quote.

Your requirements are used for engineering review and quotation. Privacy policy. Send drawings as email attachments; this form sends text only.

Email drawings directly ↗